18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

Model NO.: Overhead Covers Conductors Thick
Voltage Rating: 12/20kv, 18/30kv
Standard: En 50397-1
Sheath: HDPE Compound
Trademark: Hongda Cable
Transport Package: Steel & Wooden Drum
Specification: 1.6*1.1
Origin: Made in China
HS Code: 8544601200
Model NO.: Overhead Covers Conductors Thick
Voltage Rating: 12/20kv, 18/30kv
Standard: En 50397-1
Sheath: HDPE Compound
Trademark: Hongda Cable
Transport Package: Steel & Wooden Drum
Specification: 1.6*1.1
Origin: Made in China
HS Code: 8544601200
18/30 kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

Application: Overhead single core cables with aluminum alloy conductor and XLPE insulation, for overhead power transmission and distribution lines  up to 20 K & 33 KV.
The Covered Conductor Thick (CCT) system, although not a touch-safe screened cable system, is designed to provide protection from initiation of flash-overs due to clashing of conductors, bird or animal incursions, and tree branches or debris which has blown or fallen on to the line , specially in Weather conditions pollution.
 

ENGINEERING  SPECIFICATIONS

Standard  EN 50397-1
Rated Voltage  12/20 or 18/30 kv
Conductor  stranded aluminum alloy wire(AAAC) or ACSR.
Core  the conductor is  insulated with a layer of extruded XLPE .
Sheath  over the insulated core is applied an outer protecting  layer of extruded HDPE compound.
 Operating temperature  90°c continues normal operation.

Overhead Covers Conductors STRUCTURE:

18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables


Technical Specification according to EN 50397 CCT:
Description of property Unit of measurement Amounts/Specifications
All Aluminum Alloy Conductors (AAAC) Aluminum conductor steel reinforced (ACSR)
Size mm2 70 120 185 MINK HYENA WOLF
Conductor Construction N x mm 7x3.75 19x2.95 19x3.50 ST 1x3.66
AL 6x3.66
ST 7x1.93
AL 7x4.39
ST 7x2.59
AL 30x2.59
Cross Section mm2 77.3 129.9 182.8 73.6 126.4 194.9
Conductor diameter (compacted) mm 10.69 14.01 16.63 10.21 13.55 16.86
Covering type - XLPE / Black HDPE
Tensile Strength KN 21.67 36.39 51.23 20.59 38.86 65.46
Electrical Resistance at 20ºC Ohm/km 0.4467 0.2674 0.1900 0.4767 0.2843 0.1920
Rated voltage kV 20 33 20 33 20 33 20 33 20 33 20 33
Covering Thickness
(two Layers)
Min mm 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0
  Max mm 6.2 9.1 6.2 9.1 6.2 9.1 6.2 9.1 6.2 9.1 6.2 9.1
  Min at place mm 4.85 7.10 4.85 7.10 4.85 7.10 4.85 7.10 4.85 7.10 4.85 7.10
HDPE Thickness Min mm 1.1 1.6 1.1 1.6 1.1 1.6 1.1 1.6 1.1 1.6 1.1 1.6
  Max mm 1.6 2.2 1.6 2.2 1.6 2.2 1.6 2.2 1.6 2.2 1.6 2.2
Overall Diameter Min mm 21.6 26.6 24.8 29.8 27.5 32.5 21.1 26.1 24.5 29.5 27.8 32.8
  Max mm 23.2 29.0 26.4 32.2 29.1 34.9 22.7 28.5 26.1 31.9 29.4 35.2
Mass per Unit Length Kg/km 484 672 682 895 867 1100 514 698 758 967 1076 1311

18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

Please contact us for technical support with the right cable selection for your power distribution projects and to discuss your maintenance or project specific requirements. We provide tailored solutions for this cable range which include storage, cutting to length, and 2 days collection as standard.

Any problem and inquiry pls contact with Vivian Yuan.
Phone number: +86-15838290725 

18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables 18/30 kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

Application: Overhead single core cables with aluminum alloy conductor and XLPE insulation, for overhead power transmission and distribution lines  up to 20 K & 33 KV.
The Covered Conductor Thick (CCT) system, although not a touch-safe screened cable system, is designed to provide protection from initiation of flash-overs due to clashing of conductors, bird or animal incursions, and tree branches or debris which has blown or fallen on to the line , specially in Weather conditions pollution.
 

ENGINEERING  SPECIFICATIONS

Standard  EN 50397-1
Rated Voltage  12/20 or 18/30 kv
Conductor  stranded aluminum alloy wire(AAAC) or ACSR.
Core  the conductor is  insulated with a layer of extruded XLPE .
Sheath  over the insulated core is applied an outer protecting  layer of extruded HDPE compound.
 Operating temperature  90°c continues normal operation.

Overhead Covers Conductors STRUCTURE:

18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables


Technical Specification according to EN 50397 CCT:
Description of property Unit of measurement Amounts/Specifications
All Aluminum Alloy Conductors (AAAC) Aluminum conductor steel reinforced (ACSR)
Size mm2 70 120 185 MINK HYENA WOLF
Conductor Construction N x mm 7x3.75 19x2.95 19x3.50 ST 1x3.66
AL 6x3.66
ST 7x1.93
AL 7x4.39
ST 7x2.59
AL 30x2.59
Cross Section mm2 77.3 129.9 182.8 73.6 126.4 194.9
Conductor diameter (compacted) mm 10.69 14.01 16.63 10.21 13.55 16.86
Covering type - XLPE / Black HDPE
Tensile Strength KN 21.67 36.39 51.23 20.59 38.86 65.46
Electrical R

Lan Cable

Lan cable include CAT7 Lan Cable, cat6a cable, cat6 cable, cat5e cable.
The length of the lan cable are 1000ft (305m), the usable part of a box cable is about 300 meters. To press the RJ45 connectors, usually needs to consider the consumption of part of zhuan degree, so one box of lan cable is 305 meters.
Home Network Cable is called "twisted pair". About twisted pair:
Twisted Pair (TP), the most commonly used transmission medium in comprehensive wiring projects, consists of two insulated copper wires. By stranding two insulated copper wires together at a certain density, the radio waves emitted by each wire during transmission are offset by those from the other wire, effectively reducing the degree of signal interference.

Twisted-pair wires are usually made of two 22-26 insulated copper wires wrapped around each other, hence the name "twisted-pair wire".In practice, twisted pair consists of several pairs of twisted pair wrapped together in an insulated cable sleeve.If one or more pairs of twisted-wire is placed in an insulating bushing, it becomes a twisted-wire cable. However, in daily life, "twisted-wire" is generally referred to as "twisted-wire".

Lan cable

Lan Cord,Lan Wire,Lan Cable Connector,Flat Ethernet Cable

Shenzhen Kingwire Electronics Co., Ltd. , https://www.kingwires.com