18/30kv MV Power Cables Single Cores Cables Standards
IEC 60502 Part 2(3.6/6KV to 18/30KV)
18/30kv MV Power Cables Single Cores Cables Application
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.
18/30kv MV Power Cables Single Cores Cables Construction
Conductor:Â Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2.Â
Conductor Screen:Â The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape.
Insulation:Â XLPE
Nom. Cross Section Area | Insulation Thickness at Nominal Voltage | |||||||
1.8/3KV | 3.6/6KV | 6/10KV | 8.7/15KV | 12/20KV | 18/30KV | 21/35KV | 26/35KV | |
(Um=3.6KV) | (Um=7.2KV) | (Um=12KV) | (Um=17.5KV) | (Um=24KV) | (Um=36KV) | (Um=42KV) | (Um=42KV) | |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm |
 | XLPE | XLPE | XLPE | XLPE | XLPE | XLPE | XLPE | XLPE |
10 | 2 | 2.5 | - | - | - | - | - | - |
16 | 2 | 2.5 | 3.4 | - | - | - | - | - |
25 | 2 | 2.5 | 3.4 | 4.5 | - | - | - | - |
35 | 2 | 2.5 | 3.4 | 4.5 | 5.5 | - | - | - |
50 - 185 | 2 | 2.5 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
240 | 2 | 2.6 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
300 | 2 | 2.8 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
400 | 2 | 3 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
500 - 1600Â | 2.2-2.8Â | 3.2 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene.
Separation Sheath (for armoured cable):Â The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour .
Lapped Bedding : The lapped bedding consists of Polyester non woven fabrics .
Armour (for armoured cable):Â It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour.
Outer Sheath: PVC,PE,LSZH
Installation and operation condition of cable
Operating Temperature: up to 90°C
Short Circuit Temperature( 5 seconds maximum duration ): 250°C
Bending Radius: 12 x OD
Current Rating Conditions:
Ground Temperature: 20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W
Rated Voltage Uo/U | Operating Voltage (Um) | Testing Voltage  (rms) |
18/30KV | 36KV | 63KV Â |
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Dimensional Data:
Nom. Cross-Section Area |
Nom. Insulation Thickness |
Copper Tape Thickness | Copper Wire Screen Area*Â | Unarmoured Cables | Steel Wire Armoured Cables | ||||||||
Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
Nom. Bedding Thickness |
Armour Wire Size | Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
||||||
CU | AL | CU | AL | ||||||||||
mm2 | mm | mm | mm2 | mm | mm | kg/km | mm | mm | mm | mm | kg/km | ||
50 | 8 | 0.1 | 16 | 3.2 | 65 | 4340 | 3460 | 1.8 | 3.15 | 3.5 | 75 | 8950 | 8080 |
70 | 8 | 0.1 | 16 | 3.3 | 70 | 5220 | 3930 | 1.9 | 3.15 | 3.6 | 80 | 10150 | 8860 |
95 | 8 | 0.1 | 16 | 3.4 | 74 | 6240 | 4440 | 1.9 | 3.15 | 3.7 | 84 | 11390 | 9590 |
120 | 8 | 0.1 | 16 | 3.5 | 77 | 7180 | 4910 | 2 | 3.5 | 3.8 | 89 | 13200 | 10860 |
150 | 8 | 0.1 | 25 | 3.6 | 80 | 8220 | 5420 | 2.1 | 3.5 | 4 | 92 | 14520 | 11720 |
185 | 8 | 0.1 | 25 | 3.7 | 84 | 9540 | 6040 | 2.1 | 4 | 4.1 | 97 | 17020 | 13510 |
240 | 8 | 0.1 | 25 | 3.9 | 91 | 11720 | 7110 | 2.2 | 4 | 4.3 | 104 | 19810 | 15200 |
300 | 8 | 0.1 | 25 | 4 | 95 | 13790 | 8000 | 2.3 | 4.5 | 4.5 | 108 | 23310 | 17470 |
400 | 8 | 0.1 | 35 | 4.3 | 103 | 16820 | 9430 | 2.4 | 4.5 | 4.7 | 117 | 27010 | 19620 |
500 | 8 | 0.1 | 35 | 4.5 | 110 | 21550 | 12880 | 2.5 | 4.5 | 4.9 | 124 | 31130 | 22610 |
Nominal screen area, as stated in the table, can be supplied as standard.
Nom. Cross-Section Area |
Steel Flat Wire Armoured Cables | Double Steel Tape Armoured Cables | ||||||||||
Nom. Bedding Thickness |
Armour Wire Size | Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
Nom. Bedding Thickness |
No of Steel Tapes x Nom Tape Thickness | Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
|||
CU | AL | CU | AL | |||||||||
mm2 | mm | mm | mm | mm | kg/km | mm | mm | mm | mm | kg/km | ||
50 | 1.8 | 0.8 | 3.1 | 70.2 | 7490 | 6775 | 1.8 | 2x0.5 | 3.3 | 71.2 | 7300 | 6585 |
70 | 1.9 | 0.8 | 3.2 | 74 | 8590 | 7540 | 1.9 | 2x0.5 | 3.4 | 75 | 8390 | 7335 |
95 | 1.9 | 0.8 | 3.4 | 78.5 | 9990 | 8460 | 1.9 | 2x0.5 | 3.5 | 79.3 | 9740 | 8210 |
120 | 2 | 0.8 | 3.5 | 82.2 | 11250 | 9270 | 2 | 2x0.8 | 3.6 | 84.5 | 11845 | 9875 |
150 | 2.1 | 0.8 | 3.6 | 85.6 | 12510 | 10070 | 2.1 | 2x0.8 | 3.7 | 87.9 | 13120 | 10700 |
185 | 2.1 | 0.8 | 3.7 | 89.8 | 14155 | 11100 | 2.1 | 2x0.8 | 3.9 | 92.3 | 14850 | 11800 |
240 | 2.2 | 0.8 | 3.8 | 95.4 | 16740 | 12575 | 2.2 | 2x0.8 | 4 | 97.9 | 17480 | 13320 |
300 | 2.3 | 0.8 | 4 | 100.9 | 19310 | 14120 | 2.3 | 2x0.8 | 4.2 | 103.4 | 20080 | 14900 |
400 | 2.4 | 0.8 | 4.2 | 107.8 | 22840 | 16170 | 2.4 | 2x0.8 | 4.4 | 110.3 | 23660 | 17000 |
500 | 2.5 | 0.8 | 4.4 | 115.5 | 27200 | 18610 | 2.5 | 2x0.8 | 4.6 | 118 | 28080 | 19510 |
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Electrical Data
Nom. Cross- Section Area | D C Resistance CU / AL |
A C Resistance  CU / AL |
Short Circuit Rating of Conductor CU / AL (1 sec) |
Capaci tance | Charging Current | Short Circuit Rating of Copper Wire Screen Per Core(1 sec) | Short Circuit Rating of Copper Tape Screen Per Core(1 sec) | Reactance | Inductance |
50 | 387/641 | 494/822 | 6.8/4.4 | 142 | 0.85 | 2.6 | 1 | 134 | 430 |
70 | 268/443 | 343/568 | 9.8/6.3 | 159 | 0.95 | 2.6 | 1 | 127 | 400 |
95 | 193/320 | 248/410 | 13.3/8.5 | 175 | 1.05 | 2.6 | 1.1 | 121 | 390 |
120 | 153/253 | 196/325 | 17.2/11.0 | 189 | 1.13 | 2.6 | 1.1 | 117 | 370 |
150 | 124/206 | 159/265 | 21.2/13.5 | 201 | 1.21 | 4.3 | 1.2 | 113 | 360 |
185 | 99.1/164 | 128/211 | 26.6/17.0 | 217 | 1.3 | 4.3 | 1.2 | 109 | 350 |
240 | 75.4/125 | 98/161 | 34.9/22.3 | 237 | 1.42 | 4.3 | 1.3 | 104 | 330 |
300 | 60.1/100 | 80/130 | 43.8/28.0 | 258 | 1.55 | 4.3 | 1.4 | 101 | 320 |
400 | 47.0/77.8 | 64/102 | 57.3/36.6 | 282 | 1.69 | 5.8 | 1.5 | 96 | 290 |
500 | 36.6/60.5 | 51/81 | 72.3/46.2 | 302 | 1.79 | 5.8 | 1.6 | 78 | 250 |





Â

18/30kv MV Power Cables Single Cores Cables Standards
IEC 60502 Part 2(3.6/6KV to 18/30KV)
18/30kv MV Power Cables Single Cores Cables Application
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.
18/30kv MV Power Cables Single Cores Cables Construction
Conductor:Â Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2.Â
Conductor Screen:Â The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape.
Insulation:Â XLPE
Nom. Cross Section Area | Insulation Thickness at Nominal Voltage | |||||||
1.8/3KV | 3.6/6KV | 6/10KV | 8.7/15KV | 12/20KV | 18/30KV | 21/35KV | 26/35KV | |
(Um=3.6KV) | (Um=7.2KV) | (Um=12KV) | (Um=17.5KV) | (Um=24KV) | (Um=36KV) | (Um=42KV) | (Um=42KV) | |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm |
 | XLPE | XLPE | XLPE | XLPE | XLPE | XLPE | XLPE | XLPE |
10 | 2 | 2.5 | - | - | - | - | - | - |
16 | 2 | 2.5 | 3.4 | - | - | - | - | - |
25 | 2 | 2.5 | 3.4 | 4.5 | - | - | - | - |
35 | 2 | 2.5 | 3.4 | 4.5 | 5.5 | - | - | - |
50 - 185 | 2 | 2.5 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
240 | 2 | 2.6 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
300 | 2 | 2.8 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
400 | 2 | 3 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
500 - 1600Â | 2.2-2.8Â | 3.2 | 3.4 | 4.5 | 5.5 | 8 | 9.3 | 10.5 |
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene.
Separation Sheath (for armoured cable):Â The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour .
Lapped Bedding : The lapped bedding consists of Polyester non woven fabrics .
Armour (for armoured cable):Â It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour.
Outer Sheath: PVC,PE,LSZH
Installation and operation condition of cable
Operating Temperature: up to 90°C
Short Circuit Temperature( 5 seconds maximum duration ): 250°C
Bending Radius: 12 x OD
Current Rating Conditions:
Ground Temperature: 20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W
Rated Voltage Uo/U | Operating Voltage (Um) | Testing Voltage  (rms) |
18/30KV | 36KV | 63KV Â |
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Dimensional Data:
Nom. Cross-Section Area |
Nom. Insulation Thickness |
Copper Tape Thickness | Copper Wire Screen Area*Â | Unarmoured Cables | Steel Wire Armoured Cables | ||||||||
Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
Nom. Bedding Thickness |
Armour Wire Size | Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
||||||
CU | AL | CU | AL | ||||||||||
mm2 | mm | mm | mm2 | mm | mm | kg/km | mm | mm | mm | mm | kg/km | ||
50 | 8 | 0.1 | 16 | 3.2 | 65 | 4340 | 3460 | 1.8 | 3.15 | 3.5 | 75 | 8950 | 8080 |
70 | 8 | 0.1 | 16 | 3.3 | 70 | 5220 | 3930 | 1.9 | 3.15 | 3.6 | 80 | 10150 | 8860 |
95 | 8 | 0.1 | 16 | 3.4 | 74 | 6240 | 4440 | 1.9 | 3.15 | 3.7 | 84 | 11390 | 9590 |
120 | 8 | 0.1 | 16 | 3.5 | 77 | 7180 | 4910 | 2 | 3.5 | 3.8 | 89 | 13200 | 10860 |
150 | 8 | 0.1 | 25 | 3.6 | 80 | 8220 | 5420 | 2.1 | 3.5 | 4 | 92 | 14520 | 11720 |
185 | 8 | 0.1 | 25 | 3.7 | 84 | 9540 | 6040 | 2.1 | 4 | 4.1 | 97 | 17020 | 13510 |
240 | 8 | 0.1 | 25 | 3.9 | 91 | 11720 | 7110 | 2.2 | 4 | 4.3 | 104 | 19810 | 15200 |
300 | 8 | 0.1 | 25 | 4 | 95 | 13790 | 8000 | 2.3 | 4.5 | 4.5 | 108 | 23310 | 17470 |
400 | 8 | 0.1 | 35 | 4.3 | 103 | 16820 | 9430 | 2.4 | 4.5 | 4.7 | 117 | 27010 | 19620 |
500 | 8 | 0.1 | 35 | 4.5 | 110 | 21550 | 12880 | 2.5 | 4.5 | 4.9 | 124 | 31130 | 22610 |
Nominal screen area, as stated in the table, can be supplied as standard.
Nom. Cross-Section Area |
Steel Flat Wire Armoured Cables | Double Steel Tape Armoured Cables | ||||||||||
Nom. Bedding Thickness |
Armour Wire Size | Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
Nom. Bedding Thickness |
No of Steel Tapes x Nom Tape Thickness | Nom. Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
|||
CU | AL | CU | AL | |||||||||
mm2 | mm | mm | mm | mm | kg/km | mm | mm | mm | mm | kg/km | ||
50 | 1.8 | 0.8 | 3.1 | 70.2 | 7490 | 6775 | 1.8 | 2x0.5 | 3.3 | 71.2 | 7300 | 6585 |
70 | 1.9 | 0.8 | 3.2 | 74 | 8590 | 7540 | 1.9 | 2x0.5 | 3.4 | 75 | 8390 | 7335 |
95 | 1.9 | 0.8 | 3.4 | 78.5 | 9990 | 8460 | 1.9 | 2x0.5 | 3.5 | 79.3 | 9740 | 8210 |
120 | 2 | 0.8 | 3.5 | 82.2 | 11250 | 9270 | 2 | 2x0.8 | 3.6 | 84.5 | 11845 | 9875 |
150 | 2.1 | 0.8 | 3.6 | 85.6 | 12510 | 10070 | 2.1 | 2x0.8 | 3.7 | 87.9 | 13120 | 10700 |
185 | 2.1 | 0.8 | 3.7 | 89.8 | 14155 | 11100 | 2.1 | 2x0.8 | 3.9 | 92.3 | 14850 | 11800 |
240 | 2.2 | 0.8 | 3.8 | 95.4 | 16740 | 12575 | 2.2 | 2x0.8 | 4 | 97.9 | 17480 | 13320 |
300 | 2.3 | 0.8 | 4 | 100.9 | 19310 | 14120 | 2.3 | 2x0.8 | 4.2 | 103.4 | 20080 | 14900 |
400 | 2.4 | 0.8 | 4.2 | 107.8 | 22840 | 16170 | 2.4 | 2x0.8 | 4.4 | 110.3 | 23660 | 17000 |
500 | 2.5 | 0.8 | 4.4 | 115.5 | 27200 | 18610 | 2.5 | 2x0.8 | 4.6 | 118 | 28080 | 19510 |
18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Electrical Data
Nom. Cross- Section Area | D C Resistance CU / AL |
A C Resistance  CU / AL |
Short Circuit Rating of Conductor CU / AL (1 sec) |
Capaci tance | Charging Current | Short Circuit Rating of Copper Wire Screen Per Core(1 sec) | Short Circuit Rating of Copper Tape Screen Per Core(1 sec) | Reactance | Inductance |
50 | 387/641 | 494/822 | 6.8/4.4 | 142 | 0.85 | 2.6 | 1 | 134 | 430 |
70 | 268/443 | 343/568 | 9.8/6.3 | 159 | 0.95 | 2.6 | 1 | 127 | 400 |
95 | 193/320 | 248/410 | 13.3/8.5 | 175 | 1.05 | 2.6 | 1.1 | 121 | 390 |
120 | 153/253 | 196/325 | 17.2/11.0 | 189 | 1.13 | 2.6 | 1.1 | 117 | 370 |
150 | 124/206 | 159/265 | 21.2/13.5 | 201 | 1.21 | 4.3 | 1.2 | 113 | 360 |
185 | 99.1/164 | 128/211 | 26.6/17.0 | 217 | 1.3 | 4.3 | 1.2 | 109 | 350 |
240 | 75.4/125 | 98/161 | 34.9/22.3 | 237 | 1.42 | 4.3 | 1.3 | 104 | 330 |
300 | 60.1/100 | 80/130 | 43.8/28.0 | 258 | 1.55 | 4.3 | 1.4 | 101 | 320 |
400 | 47.0/77.8 | 64/102 | 57.3/36.6 | 282 | 1.69 | 5.8 | 1.5 | 96 | 290 |
500 | 36.6/60.5 | 51/81 | 72.3/46.2 | 302 | 1.79 | 5.8 | 1.6 | 78 | 250 |





Â
All In One Business Computer is the one of the important All In One PC series, can meet all enter and normal business application scenarios. Therefore, more and more clients choose and recommend this Business All In One Computer for business or education projects. The Best All In One Computer For Business is the similar Apple design, competitive and attractive, the hottest parameters is 19 or 21.5 inch intel i3 or i5 2th or 3th or 4th 4 gb ram 128GB ssd . There are many other all In One Computers For Business with lighter weight. Of course, you can see Colorful All In One Gaming PC, All In One Desktop Touch Screen and All In One Business Pc. Believe you can always find the right one at this store. To save time, You can also contact us by email or calling directly to get matched and valuable information fast.
Any other special configuration interest, also feel free to let us know, will try our best to back you up.
Except all in one Custom All In One PC, 14 inch Education Laptop and 15.6 inch business laptop also available here.
All In One Business Computer,Business All In One Computer,Best All In One Computer For Business,all In One Computers For Business,All In One Business Pc
Henan Shuyi Electronics Co., Ltd. , https://www.sycustomelectronics.com