- Model NO.: RSV-15A
- Heat Temperature: 30c-50c
- Heat Source: Air-source
- Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
- Products Type: DC Inverter Air Source Heat Pump
- Function: House Heating Cooling Hot Water
- Controller: Hitachi DC Inveter
- Refrigerant: R410A
- Power Supply: 220V/1pH/50Hz
- Transport Package: Strong Export Plywood Case or Wooden Box
- Origin: Danyang City, Jiangsu Province, China
- Energy Efficiency Grade: One
- Work Environment: Low-temperature Heat Pump
- Heating Type: Circulating Heat
- Certification: CE, ISO9001, CCC, CB, UL
- Compressor Brand: Mitsubishi DC Inverter
- Working Ambient Temp.: -25deg.C ~45deg.C
- Scop: a++
- Name Brand: Sunchi
- Trademark: SUNCHI / OEM
- Specification: CB/CE/ISO9001/SGS/ROHS
- HS Code: 8418612090
SUNCHI Energy Company BriefÂ
Jiangsu sunchi new energy Co.,Ltd. established in 2005, located in changzhou city , jiangsu province. with 13,000 square meters of standardized production workshop.
Â
Sunchi energy group is an professional manufacturer focus on researching, production, service of ON/OFF air source heat pump , DC inverter heat pump , ground water source heat pump and solar air conditioner .
Sunchi energy group has got the SGS,CE,CB, IEC60335-2-40, EN14511 certificate from TUV Lab, and also passed the Australia and New Zealand JAS-ANZ certificate, got ISO9001. ISO18001, ISO14001 and CCC certificate. Get Class A+, AÂ as ErP EN14825 test report .
Currently the products has been exported to Western Europe, North Europe, South Africa, Middle-East, South American and Australia market. Sunchi energy group builded new 75,000 Watts multi-function Enthalpy Difference Laboratory In 2012 year, this lab using to strictly control qulity.
Sunchi energy group company offer OEM , ODM co-operation for worldwild business partner , welcome join ours team.
Â
New style DC INVETER air heat pump
1> DC INVETER heat pump air boiler
2> cooling capacity :Â 8kw/10kw/12kw/15kw
3> Advanced DC inverter variable speed technology combine the compressor +Â fan motor +Â Â Â Â Â Â controller PCB
4> make the ambient -15ºC temp. heating capacity nearly '' 0 " loss
5> MITSUBISHI motor DC Inverter Compressor
6> SHIBAURA DC Inverter Motor
7> Sweden plate heat exchanger
8> HITACHI DC inverter controller,
9> Combine split design with DC inverter heat pump to get high SCOP
10> with CE LVD EMC certificate , as EN14825 test Erp energy level A+ when outlet is 35ºC         hot water
11> Power supply :Â 220V~240V/ 1PH /Â 50Hz ~60Hz
12> Monobloc vertical /Â Split size for choose
13> Working ambient: -25ºC~45ºC
14> Outlet water temp. range :  Heating (30ºC~50ºC ) +  Cooling  (25ºC ~5ºC)
15> refrigerant R410a
16> combine home using underfloor heating , fan coil heating /cooling , home HVAC system
Â
Model | Â | RSV-8A | RSV-12A | RSV-15A | |
HP | 3P | 5P | 6P | ||
Power supply | V/Hz | 220V/50Hz | |||
Cooling | Rated cooling capacity | kW | 8 | 12 | 15 |
Rated cooling input power | kW | 2.8 | 4 | 5.2 | |
EER | w/w | 2.9 | 3 | 2.9 | |
Cooling Min /Â Max | kW | 3.5/11 | 6/16 | 7/20 | |
EER Min /Â Max | kW | 1/4 | 1.6/6 | 1.8/6.5 | |
EER Min /Â Max | w/w | 2/4.1 | 2.1/4.1 | 2.3/4.2 | |
Heating | Rated heating capacity | kW | 6 | 8.9 | 11.2 |
Rated heating input power | kW | 2.7 | 4 | 5 | |
COP | w/w | 2.2 | 2.2 | 2.2 | |
Heating capacity Min /Â Max | kW | 2.5/8 | 4/12 | 5/15 | |
Input Power Min /Â Max | kW | 1/4 | 1.6/6 | 1.8/6.5 | |
COP Min /Â Max | w/w | 2/3.2 | 2/3.2 | 2/3.2 | |
Refrigerant | Type | R410A | |||
Compressor | Type | MITSUBISHI DC inverter | |||
Heating hot water temp. rang | ºC | 30ºC~50ºC | |||
Cooling cold water temp. rang | ºC | 5ºC~20ºC | |||
Working ambient temp. | ºC | -25ºC~45ºC | |||
Noise | dB(A) | 52 | 53 | 55 | |
N.W/ G.W | Kg | 95/103 | 108/122 | 112/130 | |
Connect pipe size | inch | Rc1" | Rc1" | Rc1" | |
If choose Split model , the following is indoor unit size : | |||||
Indoor Unit Size (L*W*H) | mm | 520*240*681 | 520*240*681 | 520*240*681 | |
The data in the above table test as following : 1. Heating test condition: ambient temp. (DB/WB):-12ºC/-14ºC,outlet water temp.:41ºC 2. Cooling test condition: ambient temp. (DB/WB): 35ºC/12ºC,outlet water temp.: 7ºC; Note : the data in this table are for reference only, please following the nameplate parameter of this product. |
FAQ :Â Marketing of SUCNHI ENERGYÂ
Q1>Â What does Sunchi energy company do ?
A1:  Sunchi energy is professional manufacturer of ON/OFF heat pump , DC inverter heat pump, air source heat pump , solar air conditioner .
Q2>Â What is the daily production of Sunchi energy company ?
A2:Â Â Sunchi energy one day produce heat pump water heater around 120~205 PCS /Â day.
Q3>Â What is SUNCHI heat pump certification ?
A3 :Â Â Sunchi energy have :Â SGS, CE,CB, IEC60335-2-40, EN14511 certificate from TUV Lab, and also passed the Australia and New Zealand JAS-ANZ certificate, got ISO9001. ISO18001, ISO14001 and CCC certificate. Get Class A+, AÂ as ErP EN14825 test report .
Q4>Â Where are the SUNCHI heat pump export to till now ?
A4 :Â Currently the products has been exported to Western Europe, North Europe, South Africa, Middle-East, South American and Australia market.
Q5>Â What is the marketing cooperation case with SUNCHI energy ?
A5:Â Â Sunchi energy all find exclusive agent /Â distributor /Â wholesale /Â OEM
     Sunchi energy is manufacturer , so we do not directly face to end user / retail ,
     After sign sales contract at this district , we will do not sales to others buyers again,
     So agent / distributor care for this district sales & service .
Q6>Â What SUNCHI energy do for their agent /Â distributor /OEM ?
A6 :  Sunchi energy offer sales training , heat pump & solar air conditioner product training,
      After sales service training , maintenance machine training , big air chiller ,or heating
      Project design case training , inside parts exchange training and test training.
Q7>Â How can get training from SUNCHI energy ?Â
A7 : If have time , can visit to my factory to training,  or invite we engineer team to yours side Â
Training , or by Video training online.
Q8> What SUNCHI energy offer to their business partner ?
A8:Â Â Sunchi enrgy offer 1%~2% free spare parts according to order quantity .
     Offer whole this district market exclusive sales right .
     Offer rebate as this district agent sales amount within one year .
     Offer best competitive price & repair parts .
     Offer 24 hours online service .
Q9>Â Â where is heat pump using ?
A9:  Because Air source heat pump save energy around 70% , ( EVI heat pump and central cooling & heating heat pump ) is Widely used in home heating, hotels hot water & heating , restaurants, hospitals,schools, bath center, residential central heating and hot water plants, etc.
Welcome visit ours factory . www.suctchenergy.com Â
    Any more question can mail us:  Â
Contact UsÂ
ON/OFF EVI heat pump water heater 12kW 19kW
90ºC high temperature heat pump water heater 20kW
Home using air source heat pump heater 5kW 35kW
Swimming pool heat pump heater 12kW 19kW 35kW 45kW
DC Inverter heat pump (Â heating +cooling )Â 8kW 12kW 15kW 18kW
Commercial heat pump air chiller 25kW 30kW 65kW 70kW 130kW
DC Inverter heat pump (Â heating+cooling+hot water )Â 12kW 15kW 25kW 30kW
Security Tool Cabinet,Metal Security Tool Cabinet,Tool Cabinet
Wecome Group Imp. & Exp. Co., Ltd. , http://www.china-vacuum-interrupter.com